Residential/ Light Commercial for Hot water or Steam

Superior design combined with industry leading efficiency makes Haydon's Hi-Output 958 the best choice for both the specifying engineer and the heating contractor. Its durable construction with standard 18 gauge front cover makes the 958 ideal for demanding residential and commercial applications, and its reliability and quiet operation are a plus in every setting.

*Other element available.
*Stocked in 2-3-4-5-6-7-8-10 foot lengths, both complete (with elements) and enclosure only (less element).



Table 1 - Heating Capacities, BTU per hr per lin. ft. 65 degrees entering air temperature I-B-R approved 

model

Nom. Tube Size

Alum.Fin
Dimensions
H X W

Thick-
ness

Fin
Spacing
Fins/Ft.

Water
Rate
GPM

Hot Water Ratings
Average Water Temperature degrees F 

Heat
Base
958-2

3/4"
CPR.

2 1/8" X 2 1/2"
Natural Finish

.015

55

4

1

150

160

170

180

190

200

210

220

230

240

590

700

790

900

1000

1110

1200

1310

1420

1510

560

660

750

850

950

1050

1140

1240

1340

1430

Heat
Base
958-1

3/4"
CPR.

2 1/8" X 2 1/2"

.008

55

4

1

150

160

170

180

190

200

210

220

230

240

480

560

790

900

1000

1110

1200

1310

1420

1510

560

660

750

850

950

1050

1140

1240

1340

1430

Heat
Base
958-3

1"
CPR.
2 3/4" X 3 1/4"

.015

54

4

1

150

160

170

180

190

200

210

220

230

240

590

700

790

900

1000

1110

1200

1310

1420

1510

560

660

750

850

950

1050

1140

1240

1340

1430

Heat
Base
958-4

1 1/4"
Steel

3 1/4" X 3 1/4"

.029

48

4

1

150

160

170

180

190

200

210

220

230

240

590

700

790

900

1000

1110

1200

1310

1420

1510

560

660

750

850

950

1050

1140

1240

1340

1430

Heat
Base
958-5

1 1/4"
CPR.

3" X 3 1/4"

.015

54

4

1

150

160

170

180

190

200

210

220

230

240

590

700

790

900

1000

1110

1200

1310

1420

1510

560

660

750

850

950

1050

1140

1240

1340

1430
All the above I-B-R Ratings are based on active length, which is 3" less than total length, and includes a 15% addition for heating effect.
Ratings: Heating capacities are listed in Table 1 for two flow rates: 1 GPM and 4 GPM. The use of I-B-R Ratings at 4 GPM is limited to installations where the water flow rate through the baseboard unit is equal to or greater than 4 GPM. Where the water flow rate through the baseboard is not known, the I-B-R Ratings at the standard flow of 1 GPM must be used.

Table 2 - Factors for ratings at flow other than standard and pressure drop values

Rate of Flow GPM

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

6.0

Factor

1.000

1.016

1.028

1.038

1.045

1.051

1.057

1.062

1.067

1.074

Pressure Drop 3/4" Tube
Mill inches per ft.

47

96

157

230

320

420

525

650

775

1060


Note: If the calculated water flow rate through a baseboard unit in a completely designed hot water heating system is greater than the standard flow rate (1 GPM), the rating of that unit may be increased by multiplying the standard I-B-R Rating at 1 GPM by the factor shown for the calculated flow rate.